Specialist diagnostics partner in the Benelux
+31 (0)85 0045479 Mon–Fri 08:30–17:00 · -
Immunology · ENA screen plus CLIA
TestLine Distributed by Goffin Diagnostics

CLIA ENA screen plus

Chemiluminescence kit for the detection of IgG antibodies to extractable nuclear antigens and centromere B in human serum or plasma.

CLIA CE-IVD TestLine 1 Package (100 Tests)
Technique
CLIA
Brand
TestLine
Packaging
1 Package (100 Tests)
Diagnostic Panel
Rheumatic Diseases
Download documentation
Runs on KleeYa® Automated CLIA Analyser See the analyser and everything it runs

Quote-based, no public pricing. Add to your quote and our specialists put together a proposal with the right documentation, typically within 24 hours.

Product details

This kit in detail

  • Detection of IgG antibodies to extractable nuclear antigens and centromere B (ENA)
  • Differential diagnosis of systemic autoimmune diseases
  • Monitoring autoimmune disease progression
  • Intended for human serum and citrate plasma
  • A mixture of native and recombinant antigens is used: Ro52/SS-A, Ro60/SS-A, La/SS-B, RNP-A, RNP-C, RNP 68, Sm, Scl-70, Jo-1, and centromere B

Description

ENA Screen is a serology test to detect IgG autoantibodies against extractable nuclear antigens (ENAs), which is a subgroup of antinuclear antibodies (ANAs) not reacting with chromatin. ENA screen is usually used following a positive result in an antinuclear antibody (ANA) test.

ENAs are mainly recognized by sera from patients with systemic lupus erythematosus (SLE), mixed connective tissue disease (MCTD), systemic sclerosis, myositis, Sjögren’s, scleroderma, polymyositis, and rheumatoid arthritis. Classical autoantigens detectable in sera from SLE patients are Smith-Protein (Sm), ribonucleoproteins (RNP), Robert-Antigen/Sjögren’s A (Ro/SSA), and Lane-Antigen/Sjögren’s B (La/SSB); they are usually completed with Scl-70 and Jo-1 antigens. The use of the centromere B antigen is an extension of the standard antigen set.

Technical data

  • Assay time: 30 min
  • Assay stability: 30 days on board stability / In use stability until the expiration date at storage temperature 2-8 °C
  • Sample matrix: Serum, Plasma
  • Sample volume: 10 μL
  • Sample stability: 7 days at 2-8 °C, 24 months at -20 °C
  • Measuring range: 3 – 320 U/ml
  • Complementary products: Anchor® Tips, Stackable Cuvette, KleeYa Trigger Pack, KleeYa Wash buffer
  • Note: The kits are CE-IVD certified and intended for professional use.

Specifications

  • Catalog Number: CL-ENA100
  • Size: 100 tests
  • Regulatory status: CE IVD
  • Clinical topic: Immunology & Autoimmune Diseases
  • Diagnostic panel: Rheumatic Diseases
  • Producer: TestLine Clinical Diagnostics s.r.o.

References

  • 19393194,20854935,20933614,20175839,20833272,20538173,20146695,22743034,15804705
  • Phan TG, Wong RC, Adelstein S. Autoantibodies to extractable nuclear antigens: making detection and interpretation more meaningful. Clin Diagn Lab Immunol. 2002 Jan;9(1):1-7. doi: 10.1128/cdli.9.1.1-7.2002. PMID: 11777822; PMCID: PMC119916.
  • Lock RJ, Unsworth DJ. Antibodies to extractable nuclear antigens. Has technological drift affected clinical interpretation? J Clin Pathol. 2001 Mar;54(3):187-90. doi: 10.1136/jcp.54.3.187. PMID: 11253128; PMCID: PMC1731369.
  • Selmi C, Ceribelli A, Generali E, Scirè CA, Alborghetti F, Colloredo G, Porrati L, Achenza MI, De Santis M, Cavaciocchi F, Massarotti M, Isailovic N, Paleari V, Invernizzi P, Matthias T, Zucchi A, Meroni PL. Serum antinuclear and extractable nuclear antigen antibody prevalence and associated morbidity and mortality in the general population over 15 years. Autoimmun Rev. 2016 Feb;15(2):162-6. doi: 10.1016/j.autrev.2015.10.007. Epub 2015 Oct 30. PMID: 26524640.
  • Sapkota B, Al Khalili Y. Mixed Connective Tissue Disease. 2021 Jan 3. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2021 Jan–. PMID: 31194355.
  • Deprettere AJ, Van Acker KJ, De Clerck LS, Docx MK, Stevens WJ, Van Bever HP. Diagnosis of Sjögren’s syndrome in children. Am J Dis Child. 1988 Nov;142(11):1185-7. doi: 10.1001/archpedi.1988.02150110063020. PMID: 3052034.
  • Lawrence JM 3rd, Moore TL, Osborn TG, Nesher G, Madson KL, Kinsella MB. Autoantibody studies in juvenile rheumatoid arthritis. Semin Arthritis Rheum. 1993 Feb;22(4):265-74. doi: 10.1016/0049-0172(93)80074-p. PMID: 8484133.
  • Reagent Cartridge with specific reagents for the assay
  • magnetic particles
  • calibrators
Documentation

Datasheets and regulatory documentation

Everything your quality team needs for evaluation and procurement.

Let’s talk diagnostics

Add this kit to your quote

Tell us the platforms and throughput you’re planning for and our specialists will put together a clear proposal with the right documentation, no public pricing, just a considered answer.