Specialist diagnostics partner in the Benelux
+31 (0)85 0045479 Mon–Fri 08:30–17:00 · -
Infectious Serology · Tetanus Toxoid CLIA
TestLine Distributed by Goffin Diagnostics

CLIA Tetanus Toxoid IgG

The chemiluminescence assay is intended for the monitoring of Tetanus Toxoid IgG antibodies in human serum or plasma in the general population.

CLIA CE-IVD TestLine 1 Package (100 Tests)
Technique
CLIA
Brand
TestLine
Packaging
1 Package (100 Tests)
Diagnostic Panel
Vaccination Monitoring
Download documentation
Runs on KleeYa® Automated CLIA Analyser See the analyser and everything it runs

Quote-based, no public pricing. Add to your quote and our specialists put together a proposal with the right documentation, typically within 24 hours.

Product details

This kit in detail

Description

Tetanus is a disease caused by the toxin produced by Clostridium tetani. The incidence of the disease has been reduced worldwide thanks to improved hygiene conditions and extensive vaccination prophylaxis. However, 400,000 to 800,000 people die from this infection every year. Most of these people live in developing countries. Vaccination-mediated protection decreases with age since tetanus antitoxin levels drop as an individual ages.

Adequate antibody protection is achieved by vaccination in childhood and subsequent booster doses. Protection starts at an anti-tetanus toxoid concentration of 0.1 IU/ml.
While the vaccine does not usually cause side effects, measuring antibody titre before the booster dose is recommended. This way, side effects such as local oedema, pain and fever can be prevented.
Sometimes, failure of the immune response may occur in patients with normal or high levels of all immunoglobulins and in patients with isolated immunodeficiencies. Therefore, normal immunoglobulin concentrations do not rule out a deficiency of anti-tetanus antibodies and the response to antigenic stimulation should be tested. If antibody tests are performed a long time after the primary and booster vaccination, abnormalities in the occurrence of cell interactions and the level of determined titres may occur.

Technical data

  • Assay time: 30 min
  • Sample matrix: Serum, Plasma
  • Sample volume: 10 μL
  • Measuring range: 0,01–5,00 IU/ml
  • Note: The kits are CE-IVD certified and intended for professional use.

Specifications

  • Catalog Number: CL-TeTG100
  • Size: 100 tests
  • Regulatory status: CE IVD
  • Clinical topic: Infectious Diseases
  • Diagnostic panel: Vaccination Monitoring
  • Producer: TestLine Clinical Diagnostics s.r.o.

References

  • 3536478,6373948,6345548,6885982,1459020,3759998,8223217
Documentation

Datasheets and regulatory documentation

Everything your quality team needs for evaluation and procurement.

Let’s talk diagnostics

Add this kit to your quote

Tell us the platforms and throughput you’re planning for and our specialists will put together a clear proposal with the right documentation, no public pricing, just a considered answer.