Taenia solium IgG ELISA Kit, tap a thumbnail to see more views.
Taenia solium IgG ELISA Kit
Taenia solium IgG ELISA Kit Cysticercosis is caused by larval cysts of the tapeworm Taenia solium and is a major cause of adult onset seizures in most developing countries. Diagnosis is based on imaging findings, but in many cases it is not conclusive for the diagnosis. Serological assays has an important place on the final diagnosis of the disease. Our ELISA kit have shown appropriate performances for the serological screening of cysticercosis.
Quote-based, no public pricing. Add to your quote and our specialists put together a proposal with the right documentation, typically within 24 hours.
This kit in detail
Taenia solium IgG ELISA Kit
Cysticercosis is caused by larval cysts of the tapeworm Taenia solium and is a major cause of adult onset seizures in most developing countries. Diagnosis is based on imaging findings, but in many cases it is not conclusive for the diagnosis. Serological assays has an important place on the final diagnosis of the disease. Our ELISA kit have shown appropriate performances for the serological screening of cysticercosis.
- High sensitivity detection of Taenia solium
- 8-wells polystyrene breakable strips
- IVDR certified
- Detection of antibodies in the serum of humans
ELISA kit for the diagnosis of human Cysticercosis
96 determinations of IgG antibodies using standard methodologies.
Wells sensitized with soluble antigens from cysts of Taenia solium.
8-wells polystyrene breakable strips: useful and economic format for laboratories with a small workload.
CE registration: CH-201808-0008
Sensitivity and specificity:
The test detects Taenia solium infections.
A sensitivity of 98% was found with 45 sera from patients suffering from subarachnoid neurocysticercosis.
A sensitivity of 71% was found with 45 sera from patients suffering from neurocysticercosis with only one viable cyst.
A sensitivity of 40% was found with 45 sera from patients suffering from neurocysticercosis with only only calcified cyst.
A specificity of 98% was found with 99 sera of blood donors (Swiss).
A specificity of 96 % was found with 100 sera from patients of an infectiology unit (Swiss).
A specificity of 13% was found with 45 patients suffering from cystic echinococcosis.
A specificity of 71% was foundwith 45 patients suffering from hymenolepiasis.
96 wells coated with soluble antigens from cysts of Taenia solium.
Dilution buffer (TBS-Tween), 50 ml
Washing solution, 50 ml
Enzyme buffer, 50 ml
Stop solution, 25 ml
Negative control serum (rabbit), 200 µl
Cut-off serum (rabbit), 200 µl
Positive control serum (rabbit), 200 µl
Protein A – AP conjugate, 300 µl
Alk. phosphatase substrate, 20 tab.
Multipipette resevoir 25ml, 1x
Frame for ELISA 8-wells holder, 1x
Instructions for use
Datasheets and regulatory documentation
Everything your quality team needs for evaluation and procurement.
Instructions for Use
Add this kit to your quote
Tell us the platforms and throughput you’re planning for and our specialists will put together a clear proposal with the right documentation, no public pricing, just a considered answer.